IDWedgeKB Firmware Update 3.4

How to update IDWedgeKB to Firmware 3.4

  1. Download the update file –IDWedgeKB_3.4.zip
  2. Download the IDWedgeKB User manual (V3.4 firmware) – IDWedgeKB-Users-Guide-Version-1.20.pdf
  3. Download IDWedgeKB Firmware upgrade procedure (same as shown below)  Upgrading-IDWedgeKB-Firmware.pdf
  4. Instructions repeated from  – Upgrading-IDWedgeKB-Firmware.pdf
  1. Unzip the update file  – (e.g. IDWedge_3.4.zip -> IDWedge_3.4.bin)
  2. Put IDWedgeKB into Flash Drive mode by Holding Function Button down and connect the IDWedgeKB USB cable to the PC.
    The Green LED should flash rapidly at about 10 flashes per second and on the PC a new drive will appear.
  3. When / If the “Do you want to scan and fix TokenWorks (drive:)?” message appears on the PC, just click continue without scanning.
  4. The TokenWorks flash drive should appear in the list of drives on the Host PC.
  5. Copy IDWedge_3.4.bin update file to TokenWorks Flash Drive using File copy commands
  6. Rename the config.txt to config.old.txt – this preserves existing settings and allows new firmware to create new Default config.txt with correct parameters and firmware version number.  If not done, a problem.txt file will be created at the end of the process stating “Config File version incorrect, erase config file and reboot to recreate config file.”  If this happens, redo this step, erase the problem.txt and reboot.
  7. Remove USB cable from PC – wait for PC to recognize the change. Then re-insert USB cable and do not push the function button.  The IDWedgeKB LED will flash green for 4 to 5 seconds and then turn Blue or White depending on Keyboard/Serial port mode setting in config.txt. (Probably Blue as that is the Default setting in config.txt)
    If the LED only flashes green for 1 or 2 seconds, the upgrade may not have taken place.  See next step to determine if upgrade occurred.
  8. To confirm the software has successfully loaded into memory, repeat step 2 (put the device into flash drive mode).  The IDWedgeKB_3.4.bin file should be erased from the TokenWorks drive.  If the file is NOT erased, then erase the IDWedgeKB_3.4.bin file and copy it onto the drive again and repeat step 6 and 7 again.
  9. Final Check – After the update has been completed, check the config.txt file.  It should have a version number of 3.4.  If there is a problem.txt file with the warning message about incorrect firmware in config.txt, then backup config.txt, erase it and reboot.  This should create new Default config.txt and erase the problem.txt file.  If necessary, copy settings from the previous config.txt file to the new config.txt file.
  1. Tip – Backup all the files on the TokenWorks drive before doing any updates.  In the event the new firmware doesn’t run as expected, delete all the files and use the backups to manual update the new files as the OS may be looking for new parameters in new versions of the file.
  2. NOTE: Version 3.4 contains a new version of the file called: Help-ReadMe.txt, which included the new formula value for the RealID field (RealID=G).  Please delete the previous version of this file from the flash drive, it will be re-written during the next reboot.



    • Related Articles

    • IDWedgeKB Demo Web page

      IDWedgeKB Demo Web page UPDATE: Now supporting Internet Explorer Version 11 — in addition to the previously and still supported latest versions of: Microsoft Edge, Mozilla FireFox, and Google Chrome Normally, almost any web page will work with ...
    • IDWedgeKB Backup Software Update Procedure

      IDWedgeKB Backup Software Update Procedure This is procedure is a backup update process in the event an IDWedgeKB is firmware is corrupted and it’s not possible to enter the standard flash drive mode It should only be done after consulting with ...
    • IDWedgeKB User Manual Version 1 12

      IDWedgeKB User Manual Version 1.12 IDWedgeKB User Manual Version 1.12 released for version 2.4 firmware – Note: Version 1.10 not published IDWedgeKB-Users-Guide-Version-1.12.pdf 1.10 Upgrade firmware to 2.4, CaC card now uses Class field for paygrade ...
    • IDWedgeBT Firmware Update – using USB Virtual Serial Port Cable and Updater software

      IDWedgeBT Firmware Update – using USB Virtual Serial Port Cable and Updater software IDWedgeBT Firmware Update – using USB Virtual Serial Port Cable and Updater software Introduction This document explains how to update the firmware in an IDWedgeBT. ...
    • IDWedge Pro Installer 2.3.1.0

      IDWedge Pro Installer 2.3.1.0 This is the full version of the IDWedge Pro software. This is a full-featured form-filling application that uses scanned driver's license data to fill in your forms. You can use it in demo mode by registering for a trial ...